Fuel tank packages · Ottawa–Gatineau
Assembled. Delivered. Locally supported.(819) 661-2801
Large white stationary fuel tank on legs in a fleet yard, with a red pump mounted at the top-front and neatly coiled black hose
MSM fuel tank packages

Stationary double-wall fuel tank on legs

For a permanent fuel storage location. A gauge monitors the vacuum between the steel walls. MSM assembles the dispensing package and coordinates tank delivery to your site.

Both bare tanks measure 70 inches in diameter. Confirm final assembled-package dimensions with MSM.

Choose your capacity
8,707 L30910323SCAFN

Choose your requested equipment

No pump and no extras are selected by default. You can edit every choice; MSM must confirm your configuration. GPM values identify the requested choice, not a guaranteed flow rate.

Fill-Rite transfer pump

Quality Fill-Rite transfer pumps. Choose your requested GPM; MSM confirms the model and setup for your operation.

Filter
Mechanical fuel-level gauge

Fuel level: separate from the base tank’s vacuum or float monitoring.

Fill-Rite meter

Add a Fill-Rite meter to track fuel dispensed. Optional; model and compatibility confirmed by MSM.

Your request summary

Tank
Stationary double-wall fuel tank on legs
Capacity
8,707 L
Transfer pump
No pump
Filter
No filter
Mechanical fuel-level gauge
No gauge
Meter
No meter

These choices are requests for MSM to confirm, not verified manufacturer specifications. MSM confirms the model, actual flow, fuel, power and compatibility, as well as the price, order and delivery arrangements before any payment.

(819) 661-2801
No pump selected. Accessories and delivery to be confirmed with MSM.

Stock and lead time confirmed with MSM. Fuel, electrical connection, installation and commissioning are not included.

Ask about the 8,707 L stationary double-wall package for delivery to your municipality.

The details, clearly

Tank specifications

Stationary double-wall fuel tank on legs · 8,707 L
Catalogue capacity8,707 L
Imperial gallons1,915
ConstructionDouble wall · stationary
MonitoringVacuum monitoring
Bare tank diameter70 in
MaterialASTM A1011 steel
FinishWhite powder-coated
Manufacturer model30910323SCAFN
Base tank manufacturerGranby Industries
Base tank standardULC-S601

Dimensions and weight refer to the bare tank, not the assembled package. They do not determine required site clearance. Catalogue capacity is not a safe fill limit.

Manufacturer information & documents

Base tank manufactured by Granby Industries. MSM is your contact to confirm requested equipment, applicable assembly, package pricing and tank delivery.

View manufacturer product page

Model identification & features

8,707 L · 30910323SCAFN · ULC-S601 (base tank)

ASTM A1011 steel, white powder-coated finish, capped 2 in NPT connections, vacuum monitoring, emergency vent, fill alarm, fill cap, grounding lug and spill box.

Options & additional information

Distribution pump protection cabinet · KV3001NC (optional; confirm model compatibility)

Hot-dipped galvanized ladder and fill platform (optional; confirm model compatibility)

Hot-dipped galvanized fill platform and staircase (optional; confirm model compatibility)

Mounting brackets for pump/dispenser, hose retriever and emergency stop opposite ladder/staircase (optional; confirm model compatibility)

Optional fill limiting kit · KV2001 (optional; confirm model compatibility)

Documented manufacturer options are separate from the equipment choices requested from MSM above. No pump is preselected. If a pump is requested, MSM confirms its model, actual flow, fuel compatibility, power requirements and applicable nozzle model. A pump manual is provided separately once the model is verified.

Documents for the selected capacity

Fuel storage, explained

Stationary double-wall fuel tanks on legs in Ottawa–Gatineau

A permanent fuel storage location calls for a different buying decision than a smaller utility tank. This stationary double-wall family offers 8,707 L and 13,013 L catalogue capacities for larger aboveground storage needs. Start with your operation’s consumption and replenishment plans, then discuss the tank, transfer equipment and receiving arrangements with MSM.

Two capacities for a permanent storage location

Both models have a confirmed bare-tank diameter of 70 inches. That shared measurement does not describe the complete assembled package or establish the space needed at your site. Ask for the dimensions of the selected configuration before making receiving arrangements.

Compare your expected fuel use between replenishments rather than choosing by capacity alone. These are catalogue capacities, not safe filling limits. If your needs are smaller, compare the utility families before settling on a stationary model.

  • 8,707 L: manufacturer model 30910323SCAFN; 1,915 imperial gallons in the catalogue.
  • 13,013 L: manufacturer model 31360323SCAFN; 2,862 imperial gallons in the catalogue.

What the double wall and vacuum gauge tell you

A second steel wall surrounds the inner tank. The gauge monitors the vacuum in the space between the walls; it is not a fuel-level gauge. This differs from the float monitoring used in the double-bottom utility family, where the monitored space is between two bottom plates.

Granby Industries manufactures the base tank, identified under ULC-S601. That designation applies to the manufacturer’s base tank, not a certification claim for the complete MSM assembly. Use the applicable manufacturer guide for monitoring and maintenance information.

Choose accessories against the selected model’s documents

The manufacturer lists the following stationary-family options. They are separate from MSM’s included transfer pump and dispensing nozzle; confirm model compatibility and the accessories included in your quote. Access equipment and mounting brackets should be discussed together, rather than assumed to come with the tank.

Equipment documents and measuring tools on a workshop desk
  • Pump protection cabinet, KV3001NC.
  • Hot-dipped galvanized ladder and fill platform.
  • Hot-dipped galvanized fill platform and staircase.
  • Mounting brackets for a pump/dispenser, hose retriever and emergency stop, opposite the ladder or staircase.
  • Fill limiting kit, KV2001.

Plan the package and receiving arrangements with MSM

MSM assembles the Granby base tank with a transfer pump and dispensing nozzle. Delivery to the agreed location is included. Tell us your municipality or postal code, selected capacity, intended fuel, access conditions and who will coordinate receipt. Discuss unloading arrangements before delivery; unloading is not guaranteed.

We serve Ottawa and Gatineau. For a nearby municipality, ask us to confirm coverage. Fuel delivery, installation, electrical connection and commissioning are not included. This is an assembled tank package, not a fully installed or turnkey fuel system. Call (819) 661-2801 to discuss your configuration and package price.

Before your request

Common questions

Can I request a stationary tank with a pump for diesel or gasoline?

Tell MSM exactly which fuel you intend to store and transfer. Tank and pump compatibility must be confirmed individually. The pump model, voltage and flow rate also need confirmation for your selected package; no single specification applies to every assembly.

Is the 70-inch diameter enough to plan delivery access?

No. It is the bare-tank diameter only. Receiving planning also requires confirmed overall package measurements and handling details. Share access constraints with MSM; do not use the diameter as a clearance or unloading specification.

Can I fill the tank to its listed catalogue capacity?

The listed capacity is not a safe fill limit. Ask for the applicable model documents and confirm filling requirements for your configuration. An optional fill limiting kit must not be assumed to be included.

Which documents should I check before choosing accessories?

Check the selected model number against the dimension drawing, capacity chart and accessories brochure. The installation and maintenance guide and written manufacturer warranty provide separate information. Ask MSM for help identifying the correct documents if a drawing title differs from the catalogue capacity.